VDC Off Indicator Lamp
VDC OFF INDICATOR LAMP
Description
Component Function Check
1. VDC OFF INDICATOR LAMP OPERATION CHECK 1
Check that the lamp illuminates for approximately 2 seconds after the ignition switch is turned ON.
Is the inspection result normal?
YES- GO TO 2
NO- Go to diagnosis procedure. Refer to "Diagnosis Procedure".
2. VDC OFF INDICATOR LAMP OPERATION CHECK 2
Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the
VDC OFF switch.
Is the inspection result normal?
YES- Inspection End.
NO- Check VDC OFF switch. VDC Off Switch.
Diagnosis Procedure
1. CHECK VDC OFF SWITCH
Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the
VDC OFF switch.
Is the inspection result normal?
YES- GO TO 2
NO- Check VDC OFF switch. VDC Off Switch.
2. CHECK SELF DIAGNOSTIC RESULT
Perform ABS actuator and electric unit (control unit) self diagnostic result. VDC/TCS/ABS.
Is the inspection result normal?
YES- GO TO 3
NO- Check items displayed by self diagnostic result. Testing and Inspection.
3. CHECK COMBINATION METER
Check if the indication and operation of combination meter are normal. Work Flow.
Is the inspection result normal?
YES- Replace ABS actuator and electric unit (control unit). VDC/TCS/ABS.
NO- Repair or replace combination meter. Removal And Installation.
Special Repair Requirement
1. ADJUSTMENT OF STEERING ANGLE SENSOR NEUTRAL POSITION
Always perform the neutral position adjustment for the steering angle sensor, when replacing the ABS actuator and electric unit (control unit). Service and Repair.
- END