ABS
ABS WARNING LAMP
Description
Component Function Check
1. CHECK ABS WARNING LAMP OPERATION
Check that the lamp illuminates for approximately 2 seconds after the ignition switch is turned ON.
Is the inspection result normal?
YES- Inspection End
NO- Go to diagnosis procedure. Refer to "Diagnosis Procedure".
Diagnosis Procedure
1. CHECK SELF DIAGNOSTIC RESULT
Perform ABS actuator and electric unit (control unit) self diagnostic result. ABS.
Is the inspection result normal?
YES- GO TO 2
NO- Check items displayed by self diagnostic result. Testing and Inspection.
2. CHECK COMBINATION METER
Check if the indication and operation of combination meter are normal. Work Flow.
Is the inspection result normal?
YES- Replace ABS actuator and electric unit (control unit). ABS.
NO- Repair or replace combination meter. Removal And Installation.