Power Supply, Ground & Circuit Elements
PRECAUTIONS
Precaution for Removing 12V Battery
1.Check that EVSE is not connected.
NOTE:
If EVSE is connected, the air conditioning system may be automatically activated by the timer A/C function.
2.Turn the power switch OFF --> ON --> OFF. Get out of the vehicle. Close all doors (including back door).
3.Check that the charge status indicator lamp does not blink and wait for 5 minutes or more.
NOTE:
If the battery is removed within 5 minutes after the power switch is turned OFF, plural DTCs may be detected.
4.Remove 12V battery within 1 hour after turning the power switch OFF --> ON --> OFF.
NOTE:
- The 12V battery automatic charge control may start automatically even when the power switch is in
OFF state.
- Once the power switch is turned ON --> OFF, the 12V battery automatic charge control does not start for approximately 1 hour.
CAUTION:
- After all doors (including back door) are closed, if a door (including back door) is opened before battery terminals are disconnected, start over from Step 1.
- After turning the power switch OFF, if "Remote A/C" is activated by user operation, stop the air conditioner and start over from Step 1.