CAN
ABS BRANCH LINE CIRCUIT
Diagnosis Procedure
1. CHECK CONNECTOR
1.Turn the power switch OFF.
2.Disconnect the 12V battery cable from the negative terminal. Refer to "Precaution for Removing 12V Battery" Precaution For Removing 12V Battery.
3.Check the terminals and connectors of the ABS actuator and electric unit (control unit) for damage, bend and loose connection (unit side and connector side).
Is the inspection result normal?
YES- GO TO 2.
NO- Repair the terminal and connector.
2. CHECK HARNESS FOR OPEN CIRCUIT
1.Disconnect the connector of ABS actuator and electric unit (control unit).
2.Check the resistance between the ABS actuator and electric unit (control unit) harness connector terminals.
Is the measurement value within the specification?
YES- GO TO 3.
NO- Repair the ABS actuator and electric unit (control unit) branch line.
3. CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the ABS actuator and electric unit (control unit). Refer to
"Diagnosis Procedure" Power Supply And Ground Circuit.
Is the inspection result normal?
YES (Present error)-Replace the ABS actuator and electric unit (control unit). Refer to "Removal and Installation" Removal And Installation.
YES (Past error)-Error was detected in the ABS actuator and electric unit (control unit) branch line.
NO- Repair the power supply and the ground circuit.