Compressor Does Not Operate
COMPRESSOR DOES NOT OPERATE
Description
SYMPTOM
Compressor does not operate.
Diagnosis Procedure
NOTE:
- Perform self-diagnoses with CONSULT before performing symptom diagnosis. If any DTC is detected, perform the corresponding diagnosis.
- Check that refrigerant is enclosed in cooler cycle normally. If refrigerant amount is shortage from proper amount, perform the inspection of refrigerant leakage.
1. CHECK REFRIGERANT PRESSURE SENSOR
Check refrigerant pressure sensor. Refer to "Diagnosis Procedure" P31EE.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair or replace malfunctioning parts.
2. CHECK A/C AUTO AMP. INPUT SIGNAL
With CONSULT
1.Select "DATA MONITOR" mode of "HVAC" using CONSULT.
2.Select "FORCED Off SIGNAL", and check status under the following conditions.
Is the inspection result normal?
YES- GO TO 3.
NO- Check for the VCM. Refer to "AIR CONDITIONER CONTROL : System Description" Air Conditioner Control.
3. CHECK A/C AUTO AMP. OUTPUT SIGNAL
With CONSULT
1.Using CONSULT, perform "HVAC TEST" on "ACTIVE TEST" of "HVAC". Refer to "CONSULT Function" CONSULT Function.
2.Check the electric compressor operations in each mode.
Is the inspection result normal?
YES- Replace A/C auto amp.
NO- Replace electric compressor.