LI-ION BATTERY GRADUAL CAPACITY LOSS DATA CLEAR

Description

Perform Li-ion Battery Gradual Capacity Loss Data Clear when the Li-ion battery or Li-ion battery controller is replaced with a new one. VCM saves the Li-ion battery deterioration information sent from the Li-ion battery controller and manages the Li-ion battery replacement timing. When the Li-ion battery or Li-ion battery controller is replaced with a new one, there is a difference between the Li-ion battery deterioration data stored in
VCM and the actual Li-ion battery deterioration level. In this case, VCM will incorrectly manage the Li-ion battery replacement timing. So perform Li-ion Battery Deterioration Data Clear to clear the Li-ion battery deterioration data stored in VCM.

CAUTION:
Never perform Li-ion Battery Deterioration Data Clear when the Li-ion battery or Li-ion battery controller is not replaced as new one.