VCM
POWER SUPPLY AND GROUND CIRCUIT
VCM : Diagnosis Procedure
1. CHECK FUSE
Check that the following fuse is not fusing.
Is the fuse fusing?
YES- Replace the fuse after repairing the applicable circuit.
NO- GO TO 2.
2. CHECK VCM GROUND CIRCUIT
1.Turn power switch OFF.
2.Disconnect VCM harness connector.
3.Check the continuity between VCM harness connector and ground.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace error-detected parts.
3. CHECK 12V BATTERY POWER SUPPLY
Check the voltage between VCM harness connector and ground.
Is the inspection result normal?
YES- GO TO 5.
NO- GO TO 4.
4. CHECK BATTERY POWER SUPPLY CIRCUIT
1.Check the continuity between VCM harness connector and fuse terminal.
2.Also check harness for short to ground.
Is the inspection result normal?
YES- Check power supply circuit for battery power supply.
NO- Repair or replace error-detected parts.
5. CHECK POWER ON POWER SUPPLY
1.Turn power switch ON.
2.Check the voltage between VCM harness connector and ground.
Is the inspection result normal?
YES- INSPECTION END
NO- GO TO 6.
6. CHECK POWER ON POWER SUPPLY CIRCUIT
1.Turn power switch OFF.
2.Disconnect IPDM E/R harness connector.
3.Check the continuity between VCM harness connector and IPDM E/R harness connector.
4.Also check harness for short to ground.
Is the inspection result normal?
YES- Replace IPDM E/R. Refer to "Removal and Installation" Removal And Installation.
NO- Repair or replace error-detected parts.