Emissions - Can't Control EVAP Vent Valve With CONSULT
Classification: EC10-029AReference: NTB10-130A
Date: November 19, 2010
2011 JUKE; EVAP VENT CONTROL VALVE DOES NOT OPERATE WITH CONSULT-III
This bulletin has been amended. Several items have been updated. Please discard previous versions.
APPLIED VEHICLES: 2011 Juke(F15)
APPLIED VINS:
2WD - Vehicles built before JN8AF(*)MR(*)BT 004461
AWD - Vehicles built before JN8AF(*)MV(*)BT 008478
APPLIED DATES: Vehicles built before September 24, 2010
IF YOU CONFIRM
The EVAP Vent Control Valve does not operate when using CONSULT-Ill (C-III) in "Work Support" or "Active Test" mode.
This incident, if it should occur, does not cause the EVAP Vent Control Valve to operate incorrectly under normal driving circumstances.
NOTE:
This bulletin does not cover any specific customer concern. Performing the ECM reprogramming in this bulletin will allow the EVAP Vent Control Valve to be operated with C-III in "Active Test" or "Work Support" mode. Additional diagnostics may be needed if there are specific concerns.
ACTIONS
1. Confirm this bulletin applies.
^ Check and compare your Current ECM Part Number to Table A shown below.
If the part number does not match one in Table A, this bulletin does not apply. Go back to ASIST for further diagnostic and repair information.
2. If this bulletin applies, reprogram the ECM.
IMPORTANT:
The purpose of "ACTIONS" (above) is to give you a quick idea of the work you will be performing. You MUST closely follow the entire Service Procedure as it contains information that is essential to successfully completing this repair.
CLAIMS INFORMATION
SERVICE PROCEDURE
1. Connect C-III to the vehicle to begin the reprogramming procedure.
CAUTION
2. When you get to the ECM Reprogramming screen shown in Figure 1 above, confirm this bulletin applies as follows:
A. On your C-III screen, look at the Part Number column (see Figure 1 above):
^ If this column is blank (no part number listed), this bulletin does not apply. Close C-III and refer to ASIST for further diagnostic information.
^ If a Part Number is listed, write it on the Repair Order.
B. Compare the Part Number you wrote down to the number in the Current ECM Part Number in Table A, above.
^ If there is a match, this bulletin applies. Continue with the reprogramming procedure.
NOTE:
If there is a match to two lines (two reprogramming options) on your C-III screen, use the one that does not have the message "Caution! Use ONLY with NTBXX-XXX".
^ If there is not a match, this bulletin does not apply. Close C-III and refer to ASIST for further diagnostic information.
3. If this bulletin applies and you have performed ECM reprogramming, the screen in Figure 2 appears when reprogramming is complete.
NOTE:
If the screen in Figure 2 does not display (reprogramming does not complete).
NOTE:
^ This bulletin does not cover any specific customer concern.
^ Performing the ECM reprogramming in this bulletin will allow the EVAP Vent Control Valve to be operated with C-III in "Active Test" or "Work Support" mode.
^ Additional diagnostics may be needed if there are specific concerns.