Without Intelligent Key System
HAZARD AND HORN REMINDER DOES NOT OPERATE
Diagnosis Procedure
1.CHECK "HAZARD LAMP SET" SETTING IN "WORK SUPPORT"
Check "HAZARD LAMP SET" setting in "WORK SUPPORT". CONSULT-III Function (BCM - Multi Remote ENT).
Is the inspection result normal?
YES - GO TO 2.
NO - Set "HAZARD LAMP SET" setting in "WORK SUPPORT".
2.CHECK "HORN CHIRP SET" SETTING IN "WORK SUPPORT".
Check "HORN CHIRP SET" setting in "WORK SUPPORT". CONSULT-III Function (BCM - Multi Remote ENT).
Is the inspection result normal?
YES - GO TO 3.
NO - Set "HORN CHIRP SET" setting in "WORK SUPPORT".
3.CHECK HAZARD WARNING LAMP
Check hazard warning lamp. Without Intelligent Key System.
Is the inspection result normal?
YES - GO TO 4.
NO - Repair or replace the malfunctioning parts.
4.CHECK HORN
Check horn. Without Intelligent Key System.
Is the inspection result normal?
YES - GO TO 5.
NO - Repair or replace the malfunctioning parts.
5.CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES - Check intermittent incident. Intermittent Incident.
NO - GO TO 1.