FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Windows: Description and Operation

POWER WINDOW

System Description
Power is supplied at all times
- from 40 A fusible link (letter I, located in the fuse and fusible link box)
- to circuit breaker terminal 1
- through circuit breaker terminal 2
- to power window relay terminal 3 and
- to front power window main switch terminal 4
- to front power window switch RH terminal 6.

With ignition switch in ON or START position power is supplied
- through 10 A fuse [No.10 located in the fuse block (J/B)]
- to rear power window switch LH and RH terminal 6
- to smart entrance control unit terminal 27.

Ground is supplied to power window relay terminal 1
- through body grounds M9, M25 and M87.

Ground is supplied to rear power window switch LH terminal 7
- through body ground B12 and B7 (without CD auto changer) or B59 (with CD auto changer).

Ground is supplied to rear power window switch RH terminal 7
- through body grounds B106 and B127.

The power window relay is energized and power is supplied
- through power window relay terminal 5
- to front power window main switch terminal 11
- to front power window switch RH terminal 13
- to rear power window switch LH and RH terminal 5.

MANUAL OPERATION

Front Door LH
Ground is supplied
- to front power window main switch terminal 5
- through body grounds M9, M25 and M87.

WINDOW UP
When the front LH switch in the front power window main switch is pressed in the up position power is supplied
- to front power window regulator LH terminal 1
- through front power window main switch terminal 2.

Ground is supplied
- to front power window regulator LH terminal 3
- through front power window main switch terminal 3.

Then the motor raises the window until the switch is released.

WINDOW DOWN
When the LH switch in the power window main switch is pressed in the down position power is supplied
- to front power window regulator LH terminal 3
- through front power window main switch terminal 3.

Ground is supplied
- to front power window regulator LH terminal 1
- through front power window main switch terminal 2.

Then the motor lowers the window until the switch is released.

Front Door RH

Ground is supplied
- to front power window switch RH terminal 5
- through body grounds M9, M25 and M87.

WINDOW UP
When the front RH switch in the front power window switch is pressed in the UP position power is supplied
- to front power window regulator RH terminal 1
- through front power window switch RH terminal 5.

Ground is supplied
- to front power window regulator RH terminal 3
- through front power window switch RH terminal 4.

Then the motor raises the window until the switch is released.

WINDOW DOWN
When the RH switch in the front power window switch is pressed in the DOWN position power is supplied
- to front power window regulator RH terminal 3
- through front power window switch RH terminal 4.

Ground is supplied
- to front power window regulator RH terminal 1
- through front power window switch RH terminal 5.

Then the motor lowers the window until the switch is released.

Rear Door
REAR DOOR
MAIN SWITCH OPERATION
Rear Door LH

Power is supplied
- through front power window main switch terminal (13, 12)
- to rear power window switch LH terminal (3, 4)

The subsequent operation is the same as front power window switch RH operation.

REAR POWER WINDOW SWITCH LH OPERATION

Power is supplied
- through rear power window switch LH terminal (1, 2)
- to rear power window regulator LH terminal (1, 2)

Ground is supplied
- to rear power window regulator LH terminal (2, 1)
- through rear power window switch LH terminal (2, 1)
- to rear power window switch LH terminal (4, 3)
- through front power window main switch terminal (12, 13)

Then the motor raises or lowers the window until the switch is released.

Rear Door RH

Power is supplied
- through front power window main switch terminal (9, 10)
- to rear power window switch RH terminal (3, 4)
- through rear power window switch RH terminal (1, 2)
- to rear power window regulator RH terminal (1, 2)

Ground is supplied
- to rear power window regulator RH terminal (2, 1)
- through rear power window switch RH terminal (2, 1)
- to rear power window switch RH terminal (4, 3)
- through front power window main switch terminal (10, 9)

Then the motor raises or lowers the window until the switch is released.

Power Window Opened/Closed Operation
- When ignition key switch is OFF front power window can be opened or closed by turning the front door key cylinder to UNLOCK/LOCK direction.
- Power window can be opened as the door key cylinder is kept fully turning to the UNLOCK direction.
- Power window can be closed as the door key cylinder is kept fully turning to the LOCK direction.

The power window opening stops when the following operations are carried out:
- While performing open/close the window power window is stopped at the position as the door key cylinder is placed on Neutral.
- When the ignition switch is turned ON while the power window opening is operated.

AUTO OPERATION
The power window AUTO feature enables the driver to open or close the driver's and passenger's side windows without holding the window switch in the down or up position.

The AUTO feature only operates on the driver's and passenger's side windows.

POWER WINDOW LOCK
The power window lock is designed to lock operation of all windows except for driver's door window. When the lock switch is pressed to lock position ground of the front and rear power window switches in the power window main switch is disconnected. This prevents the power window motors from operating.

RETAINED POWER OPERATION
When the ignition switch is turned to OFF position from ON or START position power is supplied for 45 seconds
- to power window relay terminal 2
- from smart entrance control unit terminal 46.

Ground is always supplied
- to power window relay terminal 1
- through body grounds M9, M25 and M87.

When power and ground are supplied the power window relay continues to be energized and the power window can be operated.

The retained power operation is canceled when the driver or passenger side door is opened. RAP signal's period can be changed by CONSULT-II.

INTERRUPTION DETECTION FUNCTION
Power window main switch monitors the power window regulator motor operation and the power window position (full closed or other) for driver's and passenger's side power window by the signals from encoder and limit switch in front power window regulator (driver's and passenger's side).

When power window main switch detects interruption during the following close operation in the driver's side door
- automatic close operation when ignition switch is in the "ON" position
- automatic close operation during retained power operation
- manual close operation during retained power operation

power window main switch controls driver's and passenger's side power window regulator motor for open and the power window will be lowered about 150 mm (5.91 in).