Ground Circuit Check
Ground Circuit CheckABS ACTUATOR AND ELECTRIC UNIT GROUND
- Check continuity between ABS actuator and electric unit harness connector E9 (M/T models), E169 (A/T models) terminals 16 (B), 30 (B) and ground.
Continuity should exist.