Batt/Fluid Temp (Fluid Temp Sens. Circuit & TCM Pwr. Source)
Description1 of 2
2 of 2
The A/T fluid temperature sensor detects the A/T fluid temperature and sends a signal to the TCM.
CONSULT-II REFERENCE VALUE IN DATA MONITOR MODE
Remarks: Specification data are reference values.
ON BOARD DIAGNOSIS LOGIC
DIAGNOSTIC TROUBLE CODE (DTC) CONFIRMATION PROCEDURE
After the repair, perform the following procedure to confirm the malfunction is eliminated.
With CONSULT-II
1) Start engine.
1 of 2
2 of 2
2) Select "DATA MONITOR" mode for "A/T" with CONSULT-II.
3) Drive vehicle under the following conditions:
Selector lever in "D", vehicle speed higher than 20 km/h (12 MPH).
Without CONSULT-II
1) Start engine.
2) Drive vehicle under the following conditions:
Selector lever in "D", vehicle speed higher than 20 km/h (12 MPH).
3) Perform self-diagnosis.
Refer to TCM Self-diagnostic Procedure (No Tools).
Wiring Diagram-AT-BA/FTS
TRANSMISSION CONTROL MODULE TERMINALS AND REFERENCE VALUE BETWEEN TERMINAL AND G90UND
Diagnostic Procedure
1 CHECK TCM POWER SOURCE
2 CHECK A/T FLUID TEMPERATURE SENSOR WITH TERMINAL CORD ASSEMBLY
3 CHECK INPUT SIGNAL OF A/T FLUID TEMPERATURE SENSOR (WITH CONSULT-II)
4 CHECK INPUT SIGNAL OF A/T FLUID TEMPERATURE SENSOR (WITHOUT CONSULT-II)
5 CHECK DTC
Component Inspection
A/T FLUID TEMPERATURE SENSOR
1 of 2
2 of 2
- Check resistance between two terminals while changing temperature as shown.