Charge Lamp/Indicator: Description and Operation
System DescriptionWith the ignition switch in the ON or START position, power is supplied:
- through 10 A fuse (No. [12], located in the fuse block [J/B])
- to combination meter terminal (17).
Ground is supplied:
- to combination meter terminals (24) and (56)
- through body grounds (M2) and (M61).
Ground is supplied:
- to fuel level sensor unit terminal (E) and
- seat belt buckle switch terminal (2)
- through body grounds (B13) and (B19)
Ground is supplied:
- to brake fluid level switch terminal (2)
- through body grounds (E10) and (E34).
Ground is supplied
- to washer fluid level switch terminal (2)
- through body grounds (E10) and (E34)
CHARGE WARNING LAMP
During prove out or when a generator malfunction occurs, ground is supplied:
- to combination meter terminal (63)
- from generator terminal (L).
With power and ground supplied, the charge warning lamp and brake lamp illuminate.