Without Scan Tool
WITHOUT CONSULT-IIAfter a malfunction is repaired, return to User mode from Diagnosis mode by switching the ignition "OFF" for at least 1 second, then back "ON". At that time, the self-diagnosis result is cleared.
HOW TO CHANGE SELF DIAGNOSIS MODE - Without CONSULT II
From User mode to Diagnosis mode
Diagnosis mode can be activated only when a malfunction is detected, by pressing the driver's door switch at least 5 times within 7 seconds after turning the ignition switch ON. SRS will not enter Diagnosis mode if no malfunction is detected.
From Diagnosis mode to User mode
To return to User mode while a malfunction is detected, turn ignition switch OFF, then back ON and press the driver's door switch at least 5 times within 7 seconds.
After a malfunction is repaired, turn ignition switch OFF for at least one second, then back ON. Diagnosis mode returns to User mode.