How to Clear Diagnostic Trouble Codes
CLEARING DIAGNOSTIC TROUBLE CODESTo erase Diagnostic Trouble Codes from the control module memory, disconnect the check terminal from the ground. Within 12.5 seconds of disconnecting the check terminal from the ground, ground the check terminal again three times for a period of at least one second. The ABS warning lamp should remain ON while erasing the malfunction (trouble) codes, and should go out after the erase mode has been completed. After erasing the malfunction (trouble) codes, rerun the self-diagnostic mode to verify that the malfunction (trouble) codes no longer appear.