Oxygen Sensor: Service and Repair
Oxygen Sensor:
REMOVAL
1. Disconnect harness terminal.
2. Remove sensor with suitable socket or wrench.
INSTALLATION
1. Apply a thin coating of anti-seize compound to the threads.
NOTE: Do not contaminate sensing tip with compound.
2. Install sensor and torque it to 40 - 50 N-m (4.1 - 5.1 kg-m, 30 - 37 lb.ft.).
3. Apply a thin coating of dielectric compound to the connector.
4. Connect harness terminal.