Connecting Rod: Testing and Inspection
BEND AND TORSION
The bending limit is 0.15 mm (0.0059 inch) per 100 mm (3.94 inch) length.
The torsional limit is 0.30 mm (0.0118 inch) per 100 mm (3.94 inch) length.
If the limits are exceeded, replace the connecting rod assembly.