Positive Crankcase Ventilation: Testing and Inspection
Fig. 3 Testing PCV valve (typical):
With engine running at idle, remove the ventilator hose from PCV valve; if the valve is working, a hissing noise will be heard as air passes through the valve and a strong vacuum should be felt immediately when a finger is placed over valve inlet, Fig. 3.