Turn Signal Flasher: Testing and Inspection
Electrical Components InspectionCOMBINATION FLASHER UNIT CHECK
- Before checking, ensure that bulbs meet specifications.
- Connect a battery and test lamp to the combination flasher unit, as shown. Combination flasher unit is properly functioning if it blinks when power is supplied to the circuit.
Ground is supplied to rear combination lamp RH terminal 2 through body grounds B106 and B116.
Ground is supplied to combination meter terminal 36 through body grounds M14 and M68.
With power and ground supplied, the combination flasher unit controls the flashing of the hazard warning lamps.