With Automatic Climate Control
TROUBLE DIAGNOSIS PROCEDURE FOR MAGNET CLUTCHInspection Flow:
SYMPTOM:
- Magnet clutch does not engage.
SYSTEM DESCRIPTION
Auto amplifier controls compressor operation by ambient temperature and signal from ECM.
Low Temperature Protection Control
Auto amplifier will turn the compressor "ON" or "OFF" as determined by a signal detected by ambient sensor.
When ambient temperatures are greater than 1° C (34° F), the compressor turns "ON". The compressor turns "OFF" when ambient temperatures are less than -2° C (28° F).
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
Step 7:
Step 8:
Step 9:
Step 10:
DIAGNOSTIC PROCEDURE
SYMPTOM: Magnet clutch does not engage when AUTO switch is ON.
COMPONENT INSPECTION
A/C Relay
Check continuity between terminal Nos. 3 and 5.
If NG, replace relay.
Dual-pressure Switch