P0135
SYSTEM DESCRIPTION
The ECM performs ON/OFF control of the front heated oxygen sensor heaters corresponding to the engine speed.
OPERATION
Engine speed rpm Front heated oxygen sensor heaters
Above 3,200 OFF
Below 3,200 ON
CONSULT Reference Value in Data Monitor Mode
Specification data are reference values.
ECM Terminals and Reference Value
Specification data are reference values and are measured between each terminal and 32 (ECM ground).
On Board Diagnosis Logic
DTC Confirmation Procedure
NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 5 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10.5V and 16V at idle.
With CONSULT
1. Turn ignition switch "ON" and select "DATA MONITOR" mode with CONSULT.
2. Start engine and run it for at least 6 seconds at idle speed.
3. If 1st trip DTC is detected, go to "Diagnostic Procedure" below.
With GST
1. Start engine and run it for at least 6 seconds at idle speed.
2. Turn ignition switch "OFF" and wait at least 5 seconds.
3. Start engine and run it for at least 6 seconds at idle speed.
4. Select "MODE 3" with GST.
5. If DTC is detected, go to "Diagnostic Procedure" below.
Without Scan Tool
1. Start engine and run it for at least 6 seconds at idle speed.
2. Turn ignition switch "OFF", wait at least 5 seconds and then turn "ON".
3. Perform "Diagnostic Test Mode II (Self-diagnostic results)" with ECM.
4. If 1st trip DTC is detected, go to "Diagnostic Procedure" below.
- When using GST, "DTC Confirmation Procedure" should be performed twice as much as when using CONSULT or ECM (Diagnostic Test Mode II) because GST cannot display MODE 7 (1st trip DTC) concerning this diagnosis. Therefore, using CONSULT or ECM (Diagnostic Test Mode II) is recommended.
EC-FO2H-R-01:
EC-FO2H-R-01 Connectors View:
Wiring Diagram RIGHT BANK
Diagnostic Procedure
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Component Inspection
Check resistance between terminals 3 and 1.
Resistance: 2.3 - 4.3 (ohms) at 25°C (77°F)
Check continuity between terminals 2 and 1, 3 and 2.
Continuity should not exist.
If NG, replace the front heated oxygen sensor.
CAUTION:
- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.