From VIN # 350001
System Description:
SYSTEM DESCRIPTION
The ECM performs ON/OFF control of the front heated oxygen sensor heaters corresponding to the engine speed.
Operation:
OPERATION
CONSULT Reference Value In Data Monitor Mode:
CONSULT Reference Value in Data Monitor Mode
Specification data are reference values.
ECM Terminals And Reference Value:
ECM Terminals and Reference Value
Specification data are reference values and are measured between each terminal and 32 (ECM ground).
On Board Diagnosis Logic:
DTC Confirmation Procedure
NOTE: If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 5 seconds before conducting the next test.
TESTING CONDITION: Before performing the following procedure, confirm that battery voltage is between 10.5 V and 16V at idle.
With CONSULT
1. Turn ignition switch "ON" and select "DATA MONITOR" mode with CONSULT
2. Start engine and run it for at least 6 seconds at idle speed.
3. If 1st trip DTC is detected, go to "Diagnostic Procedure".
With GST
1. Start engine and run it for at least 6 seconds at idle speed.
2. Turn ignition switch "OFF" and wait at least 5 seconds.
3. Start engine and run it for at least 6 seconds at idle speed.
4. Select "MODE 3" with GST.
5. If DTC is detected, go to "Diagnostic Procedure".
No Tools
1. Start engine and run it for at least 6 seconds at idle speed.
2. Turn ignition switch "OFF", wait at least 5 seconds and then turn "ON".
3. Perform "Diagnostic Test Mode II (Self-diagnostic results)" with ECM.
4. If 1st trip DTC is detected, go to "Diagnostic Procedure".
- When using GST, "DTC Confirmation Procedure" should be performed twice as much as when using CONSULT or ECM (Diagnostic Test Mode II) because GST cannot display MODE 7 (1st trip DTC) concerning this diagnosis. Therefore, using CONSULT or ECM (Diagnostic Test Mode II) is recommended.
EC-FO2H-L-01:
Wiring Diagram
Fuse Block J/B Connector Views:
Steps 1 - 2:
Steps 3 - 5:
Diagnostic Procedure
Component Inspection
FRONT HEATED OXYGEN SENSOR HEATER
Check resistance between terminals 3 and 1.
Resistance: 2.3- 4.3 ohms at 25°C (77°F)
Check continuity between terminals 2 and 1, 3 and 2.
Continuity should not exist.
If NG, replace the front heated oxygen sensor.
CAUTION:
- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.