Inspection Procedure 19
Inspection Procedure 19: Distortion on FM only.
DIAGNOSTIC PROCEDURE
STEP 1. Check with another broadcasting station.
Q. Is there distortion when turning to another broadcasting station?
YES Go to Step 2.
NO The signal from that station is too weak.
STEP 2. Relocate the reception area and check.
Q. When relocating the reception area does the distortion increase or decrease?
YES The cause may be multipath noise.
NO Repair or replace the radio and CD player. Check that a distortion is resolved.