Transfer Case Actuator Relay: Testing and Inspection
ELECTRIC PUMP RELAY CHECK
1. Using a jumper wire, connect the positive battery terminal (+) to the electric pump relay terminal No.3, and the negative battery terminal (-) to the terminal No.1.
2. Check for continuity between the electric pump relay terminals No.2 and No.4.
3. If defective, replace the electric pump relay.