Seat Cushion Heater Check
SEAT CUSHION HEATER CHECKMeasure the resistance between terminals.
Standard value: At room temperature 20° C (68° F)
Between terminals 2 and terminal 3: Approximately 3.98 ohms ± 5%
Between terminals 1 and terminal 3:3.98 ohms ± 5%
NOTE: When the interior temperature rises 1° C ( 34° F), a measurement standard value increases 0.031 ohms. And when the interior temperature drops 1° C ( 34° F), a measurement standard value decreases 0.031 ohms.