Reprogramming Procedure
REPROGRAMMING PROCEDUREBATTERY VOLTAGE (AS MEASURED AT THE BATTERY POSTS WITHOUT ELECTRICAL LOAD) MUST BE KEPT AT 12.4V OR HIGHER IN ORDER TO REPROGRAM THE ECM. MEASURE THE BATTERY VOLTAGE AND CHARGE AS NECESSARY. A BATTERY CHARGER SHOULD BE CONNECTED TO THE VEHICLE'S BATTERY DURING THE REPROGRAMMING PROCEDURE. DO NOT ALLOW THE BATTERY CHARGER TO TIME OUT.
NOTE:
VCI Stand-alone reprogramming is not available for this procedure. The laptop and the VCI must remain connected for the entire procedure.
Connect the equipment as follows:
^ Turn the laptop computer on. If the battery charge indicator in the lower right hand corner of the screen does not show a full charge, it is recommended that either the laptop battery be charged prior to beginning, or that reprogramming be completed with the A/C power adaptor connected to the laptop.
^ Connect the USB cable to the VCI.
^ When the laptop displays the MUT-III main screen, connect the USB cable to the laptop.
^ Connect the MUT-III main harness with the blue DLC connection to the VCI.
^ Connect the blue connector of the MUT-III main harness to the vehicle's data link connector.
^ Turn the VCI power switch ON. Verify that the indicator lamp in the upper right corner of the screen is green.
CAUTION:
DO NOT DISTURB THE HARNESS CABLES OR CONNECTIONS. INTERRUPTION DURING THE REPROGRAMMING PROCESS COULD CAUSE THE CONTROL UNIT TO LOSE DATA OR PREVENT FUTURE REPROGRAMMING. IF THE USB CABLE IS DISCONNECTED DURING THIS PROCEDURE, A WARNING MESSAGE WILL DISPLAY.