FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Leak Detection Solenoid: Testing and Inspection

INSPECTION

EVAPORATIVE EMISSION VENTILATION SOLENOID CHECK




1. Connect a hand vacuum pump to nipple (A) of the solenoid.
2. Check air tightness by applying a vacuum with voltage applied directly from the battery to the evaporative emission ventilation solenoid and without applying voltage.









3. Measure the resistance between the terminals of the solenoid.

Standard value: 17 - 21 ohms [at 20 °C (68 °F)]