Introduction to Power Window Diagnosis
POWER WINDOW DIAGNOSISINTRODUCTION TO POWER WINDOWS DIAGNOSIS
The quarter window is controlled by the convertible top control module. For troubleshooting, refer to Electric Convertible Top Diagnosis. When the power window main switch is operated, the quarter window regulator motor operates and opens or closes the quarter window.
A timer function has been provided to allow the quarter windows to be opened or closed in 30 seconds after the ignition switch is turned from "ON" to "LOCK" (OFF) position when a door's are closed (door switch is OFF).
If the following types of symptom occur, check the Convertible top control module diagnosis code.
- None of the quarter windows open or close.
- There are quarter windows that do not open or close using the power window main switch.
- When parking there are quarter windows that do not open using the convertible top switch.
If the windows cannot be opened or closed using the power window main switch within 30 seconds after the ignition switch is turned from "ON" to "LOCK" (OFF) position, refer to Simplified Wiring System (SWS) - Diagnosis.