Radiator Cooling Fan Control Module: Testing and Inspection
FAN CONTROL MODULE CHECK [3.8L ENGINE]FAN CONTROL MODULE CHECK <3.8L ENGINE>:
1. Remove the fan control module connector.
2. Turn the ignition switch to the "ON" position, and measure the voltage between the harness-side connector terminals.
Standard value: Battery positive voltage
3. Connect the fan control module connector, and disconnect the condenser fan motor connector.
4. Ensure that the A/C switch is off, and start the engine and run it at idle.
5. Measure the voltage between the fan control module-side connector terminals.
Standard value: 1 volt or less
WARNING: Stay clear of the fan when the fan starts running.
6. Turn the A/C switch to the "ON" position.
7. Measure the voltage between the fan control module-side connector terminals while the fan is running. The voltage should repeat the values 1) and 2) below.
Standard value:
1) 8.2 ±2.6 volts
2) Battery positive voltage ±2.6 volts
8. If the voltage does not repeatedly change as indicated, replace the radiator fan motor.