Inspection Procedure 6
INSPECTION PROCEDURE 6: Door does not Open or Close CompletelyDIAGNOSIS
STEP 1. Check the door hinge position.
Q: Is the door hinge correct?
YES: Go to Step 2.
NO: Adjust the door hinge. Then go to Step 4.
STEP 2. Check the door for damage.
Q: Is the door in good condition?
YES: Go to Step 3.
NO: Repair or replace the door, then go to Step 4.
STEP 3. Check lubrication.
Q: Are the door check and door hinge sufficiently lubricated?
YES: Go to Step 4.
NO: Apply grease, then go to Step 4.
STEP 4. Retest the system.
Q: Does the door open and close completely?
YES: The procedure is complete.
NO: Return to Step 1.