FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Inspection Procedure H-3

Rear Wiper and Washer: When the Selector Lever is Moved to "R" Position during the Rear Wiper Operation, the Rear Wiper does not Operate at the Continuous Mode.

"R" Position During Rear Wiper Operation Circuit:






NOTE: This troubleshooting procedure requires use of scan tool MB991958 and SWS monitor kit MB991813. For details on how to use the SWS monitor, refer to "How to use SWS monitor." How To Use SWS Monitor

CIRCUIT OPERATION
The ETACS-ECU operates the rear wiper consecutively approximately twice when the selector lever is moved to "R" position while the rear wiper is turned on.

TECHNICAL DESCRIPTION (COMMENT)
If the rear wiper does not work consecutively approximately twice, the transmission range switch ("R" position) or the ETACS-ECU may be defective.

TROUBLESHOOTING HINTS
- The transmission range switch may be defective
- The ETACS-ECU may be defective
- The wiring harness may be damaged or the connectors may have loose, corroded or damaged terminals, pushed back in the connector

DIAGNOSIS

Required Special Tools:
- MB991223: Harness Set
- MB991958: Scan Tool (MUT-III Sub Assembly)
- MB991824: Vehicles communication interface (V.C.I.)
- MB991827: MUT-III USB cable
- MB991911: MUT-III Main harness B
- MB991813: SWS monitor kit
- MB991806: SWS monitor cartridge
- MB991812: SWS monitor harness (for column-ECU)
- MB991922: Probe harness

STEP 1. Verify the rear wiper.

Q: Does the rear wiper operate?

YES: Go to Step 2.

NO: Refer to Inspection Procedure H-1 "Rear wiper does not work at all."

STEP 2. Check the input signal by using "FUNCTION DIAG." menu of the SWS monitor.
Set each switch to the following condition before checking input signal from the transmission range switch ("R" position).
- Ignition switch: ON
- Rear wiper switch: ON
- Shift position: R position

CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958. Connect special tool MB991910 before connecting special tool MB991812. Be sure to connect special tool MB991806 after turning on special tool MB991824.







1. Connect the special tool. Refer to "How to connect SWS monitor." How to Connect SWS Monitor
2. Operate scan tool MB991958 according to the procedure below to display "REV.INTER LOCK."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f. Select "REAR WIPER."
g. Select "REV.INTER LOCK."




3. Check that normal conditions are displayed on the item described in the table.

Q: Are normal conditions displayed?

YES: Replace the ETACS-ECU. When the selector lever is moved to the "R" position, the rear wiper should operate consecutively approximately twice.

NO: Refer to Inspection Procedure O-4 "ETACS-ECU does not receive "R" position signal from the backup light switch " or Inspection Procedure O-5 "ETACS-ECU does not receive "R" position signal from the transmission range switch ."