Air Bypass Valve: Testing and Inspection
TURBOCHARGER BYPASS VALVE CHECK
1. Remove the turbocharger bypass valve.
2. Connect the hand vacuum pump to the nipple of the turbocharger bypass valve.
3. Apply a negative pressure of approximately 53 kPa (16 in.Hg) and check operation of the valve. Also check that air tightness is maintained.