Inspection Procedure 4
Blower Fan And Motor Does Not Turn.STEP 1. Check the blower relay continuity.
Follow the table to check the blower relay for continuity.
Q: Is the blower relay continuity in good condition?
YES: Go to Step 2.
NO: Replace. Then go to Step 5.
STEP 2. Check the blower fan and motor operation.
When battery voltage is applied between the terminals, check that the motor operates.
Q: Is there any abnormal noise?
YES: Go to Step 3.
NO: Replace. Then go to Step 5.
STEP 3. Check the blower switch continuity.
Follow the table to check the blower switch for continuity.
Q: Is the blower switch continuity in good condition?
YES: Go to Step 4.
NO: Replace. Then go to Step 5.
STEP 4. Check the resistor resistance value.
Standard Value:
Use an Ohmmeter to measure the resistance between the terminals as indicated. Check that the measured value is at the standard value.
Q: Is the measured value at the standard value?
YES: Go to Step 5.
NO: Replace. Then go to Step 5.
STEP 5. Check symptoms.
Q: Is the blower fan and motor turned?
YES: This diagnosis is complete. (If no malfunctions are not found in all steps, an intermittent malfunction is suspected. Refer to How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction.)
NO: Go to Step 1.