Inspection Procedure 3
The Service Engine Soon/Malfunction Indicator Lamp Does Not Illuminate Right After the Ignition Switch Is Turned to the "ON" PositionService Engine Soon/Malfunction Indicator Lamp Circuit:
Connectors:
CIRCUIT OPERATION
- The service engine soon/malfunction indicator lamp power is supplied from the ignition switch.
- The ECM
COMMENT
- The ECM
TROUBLESHOOTING HINTS (The most likely causes for this case:)
- Burnt-out bulb.
- Defective service engine soon/malfunction indicator lamp circuit.
- Malfunction of the ECM
DIAGNOSIS
Required Special Tool:
- MB991502: Scan Tool (MUT-II)
STEP 1. Using scan tool MB991502, check data list item 16: Power Supply Voltage.
CAUTION: To prevent damage to scan tool MB991502, always turn the ignition switch to the "LOCK" (OFF) position before, connecting or disconnecting scan tool MB991502.
1. Connect scan tool MB991502 to the data link connector.
2. Turn the ignition switch to the "ON" position.
3. Set scan tool MB991502 to the data reading mode for item 16, Power Supply Voltage.
- Voltage should be battery positive voltage.
4. Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the voltage normal?
YES: Go to Step 2.
NO: Refer to INSPECTION PROCEDURE 29- Power Supply System and Ignition Switch-IG System.
STEP 2. Check the burned-out bulb.
Q: Is the valve normal?
YES: Go to Step 3.
NO: Replace the bulb. Then confirm that the malfunction symptom is eliminated.
STEP 3. Check connector C-01 at the combination meter for damage.
Q: Is the connector in good condition?
YES: Go to Step 4.
NO: Repair or replace it. Refer to Harness Connector Inspection. Then confirm that the malfunction symptom is eliminated.
STEP 4. Check the power supply voltage at combination meter harness side connector C-01.
1. Disconnect the connector C-01 and measure at the harness side.
2. Turn the ignition switch to the "ON" position.
3. Measure the voltage between terminal 9 and ground.
- Voltage should be battery positive voltage.
4. Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the voltage normal?
YES: Go to Step 5.
NO: Check harness connectors C-21, C-211 and C-214 at intermediate connector for damage, and repair or replace as required. Refer to Harness Connector Inspection. If intermediate connectors are in good condition, repair harness wire between ignition switch connector C-201 terminal 2 and combination meter connector C-01 terminal 9 because of open circuit. Then confirm that the malfunction symptom is eliminated.
STEP 5. Check connector C-119 at ECM
Q: Is the connector in good condition?
YES: Go to Step 6.
NO: Repair or replace it. Refer to Harness Connector Inspection. Then confirm that the malfunction symptom is eliminated.
STEP 6. Check the power supply voltage ECM connector C-119
1. Disconnect the connector C-119
2. Turn the ignition switch to the "ON" position.
3. Measure the voltage between terminal 36
- Voltage should be battery positive voltage.
4. Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the voltage normal?
YES: Replace the ECM or PCM. Then confirm that the malfunction symptom is eliminated.
NO: Check harness connectors C-124 at intermediate connector for damage, and repair or replace as required. Refer to Harness Connector Inspection. If intermediate connectors is in good condition, repair harness wire between combination meter connector C-01 terminal 17 and ECM connector C-119 terminal 36