Main Relay (Computer/Fuel System): Testing and Inspection
1. Remove the relay.
2. Check the continuity between the MFI relay terminals.
3. Use the jumper leads to connect relay terminal 4 to the battery (+) terminal and terminal 2 to the battery (-) terminal.
4. Check the continuity between relay terminals 1-3 while connecting and disconnecting the jumper lead at the battery (-) terminal.
5. If there is a defect, replace the MFI relay.