FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Initial Inspection and Diagnostic Overview

Input Signal Inspection Points:





When Using The Scan Tool (MUT-II)
1. Connect the scan tool to the data link connector.

CAUTION: Always turn the ignition switch off when connecting and disconnecting the scan tool.

2. If buzzer of the scan tool sounds once when a switch is operated (ON/OFF), the ECU input signal for that switch circuit system is normal.


Input Signal Inspection Points:





When Using The Voltmeter
1. Use the special tool to connect a voltmeter between the ground terminal and the ETACS terminal of data link connector.
2. If the voltmeter indicator deflects once when a switch is operated (ON/OFF), the ECU input signal for that switch circuit system is normal.