Symptom Related Diagnostic Procedures
SYMPTOM / PROBABLE CAUSEEngine will not start or is hard to start
- Vacuum hose disconnected or damaged.
- The Exhaust Gas Recirculation Valve is not closed.
- Malfunction of the Canister Purge Solenoid Valve.
Rough Idle or engine stalls
- The Exhaust Gas Recirculation Valve is not closed.
- Vacuum hose disconnected or damaged.
- Malfunction of the Positive Crankcase Ventilation Valve.
- Malfunction of the Canister Purge Solenoid Valve.
Engine Hesitates or poor acceleration
- Malfunction of the Exhaust Gas Recirculation System.
Excessive oil consumption
- Positive Crankcase Ventilation line plugged.
Poor fuel mileage