Neutral Safety Switch: Testing and Inspection
1. Disconnect electrical connector from switch.Fig. 29 PNP Switch N & P Position Inspection:
Fig. 30 PNP Switch N & P Position Inspection:
2. Place selector lever in the N, then P ranges to check switch. Check continuity between terminals as shown in Fig. 29 and 30.