Charging System: Testing and Inspection
1. Charging indicator light does not go on when the ignition switch is turned to "ON", before the engine starts.- Check the bulb
2. Charging indicator light fails to go off once the engine starts.
- Check the IC voltage regulator (located within the generator).
3. Discharged or overcharged battery.
- Check the IC voltage regulator (located within the generator).
4. The charging warning light illuminates dimly.
- Check the diode (within the combination meter) for a short-circuit.