Electrical Specifications
RPM at Temperature:-20 °C (-4°F) 1,500 - 1,700 RPM
0°C (32°F) 1,350 - 1,550 RPM
20°C (68°F) 1,180 - 1,350 RPM
40°C (104°F) 1100 - 1,200 RPM
80°C (176°F) 650 - 850 RPM
When cranking the engine the tachometer (cranking) RPM and Scan Tool RPM should agree.