Coolant Temperature Sensor/Switch (For Computer): Service and Repair
REMOVAL
1. Drain approximately 2 quarts of coolant from the radiator drain plug.
2. Disconnect the electrical connector.
3. Remove the sensor with a suitable socket.
INSTALLATION
1. Apply sealant to the threaded portion of the sensor.
2. Install the sensor and tighten to the specified torque.
Torque: 20 - 40 Nm (15 - 29 ft.lbs)
3. Reconnect the electrical connector.
4. Refill the radiator and check for leaks.