Fuel Gauge Circuit Inspection
Fuel Gauge Circuit Inspection:
1. Remove the IG terminal screw from area A.
2. Measure resistance between terminals with circuit tester.
Standard value:
A - B Approx. 230 ohms
A - C Approx. 102 ohms
B - C Approx. 102 ohms