Component Tests and General Diagnostics
Motor Antenna Assembly:
Following inspections should be made with the harness connector disconnected from the power antenna relay. With the (+) power connected to the terminal (11) and the (-) power to the terminal (8), check that the antenna mast extends. With the connection reversed, check that the antenna mast retracts.