Inhibitor/Neutral Safety Switch
1. Place selector lever and manual control lever in neutral position.2. Remove transaxle control cable attaching nut.
3. Disconnect electrical harness, then remove switch retaining bolts and switch assembly.
4. Reverse procedure to install, adjust switch as follows:
a. Rotate switch body so that manual control lever .2 inch hole and switch body .2 inch hole are aligned.
b. Torque switch retaining screws to 7-9 Ft. Lbs.