P150A
2E44 - P150AInformation saved in
DME
Fault code
2E44 - P150A
Fault text
Intelligent battery sensor (IBS): extended communication
faulty
Fault description
Intelligent Battery Sensor, signal transmission
Condition for fault identification
Test condition:
BSD bus active
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
25S
Action in service
1. Check BSD interface wire for intermittent shorts to UBatt
and ground
2. Check for intermittent opens
3. Disconnect other BSD interface components (alternator)
one after the other and replace as indicated
4. If fault persists after deletion of stored DTC's, replace
battery sensor
Fault effect and breakdown warning
None
none
Driver information
Warning light:
none
Service instruction
None