P13AE
2D8C - P13AEInformation saved in
DME
Fault code
2D8C - P13AE
Fault text
Knock sensor, electric
Fault description
Knock sensor, electric
Condition for fault identification
Test condition:
Engine running
Line voltage below -0.7 V
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
The error must appear 3 times in sequence in accordance
with the debounce frequency.
Otherwise the debounce counter is reset and the debounce
process starts again at the beginning.
Action in service
Check wiring harness between DME and knock sensor,
replace knock sensor,
replace DME
Fault effect and breakdown warning
None
Possible reduction in power
Driver information
Warning light:
MIL ON
EML ON (CC message: ID29)
Service instruction
None