P1020
286E - P1020Information saved in
DME
Fault code
286E - P1020
Fault text
Valvetronic, eccentric shaft sensor: Voltage supply
Fault description
Valvetronic, excentric shaft sensor: Voltage supply
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
1 sec.
Action in service
Check the voltage supply for the excentric shaft sensor
(Specified: 4.5V ... 5.5V)
Fault effect and breakdown warning
None
none
Driver information
Warning light:
none
Service instruction
None