Manufacturer Code Charts: 3096
3096 - P1721Information saved in
DME
Fault code
3096 - P1721
Fault text
No CAN message DSC
Fault description
No CAN message, DSC
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 15
Voltage condition:
Battery voltage wub (0x583C) > 10 V
Condition for fault memory entry
0.5 sec.
Action in service
If this fault has been entered frequently and/or is currently
present;
continue fault diagnosis with DSC
Fault effect and breakdown warning
None
none
Driver information
Warning light:
DSC lamp may light up
Service instruction
None