2EE6
2EE6 - P0692Information saved in
DME
Fault code
2EE6 - P0692
Fault text
Electric fan, activation
Fault description
Electric fan, control-activation: Short circuit to B+
Condition for fault identification
Test condition:
Output stage diagnosis
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
0.5 sec.
Action in service
1. Check wiring harness between fan and DME
2. Replace sensor
3. Replace DME
Fault effect and breakdown warning
None
none
Driver information
Warning light:
none
Service instruction
None