FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2E38

2E38 - P324E

Information saved in
DME

Fault code
2E38 - P324E

Fault text
Generator, regulator incorrect

Fault description
Alternator, regulator: Incorrect type

Condition for fault identification
Test condition:
The error is recognized when characteristic of the regulator
does not agree with the characteristic stored in the DME.
Terminal condition: Terminal 15
Voltage condition:
Alternator specified voltage for min. 5 sec.: high electrical
system voltage +1.0 V or greater than 14 V

Condition for fault memory entry
25.5 sec.

Action in service
- If the fault frequency is greater than or equal to 3, clear the
control module fault memory and do not take any further
action
- If the fault frequency is > 3, then replace the alternator

Fault effect and breakdown warning
None
none

Driver information
Warning light:
none

Service instruction
None